Validity, intra- and inter-observer reliability of automated devices for the assessment of ankle brachial index using photo-plethysmography

Abstract:

BACKGROUND\backslashr\backslashnAnkle-brachial-Index (ABI) measured by manual Dopplersonography is an easily assessable marker of global cardiovascular risk. The aim of this study was to establish novel photo-plethysmography (PPG)-based ABI assessments in an epidemiologic context and to compare its results with those of Doppler.\backslashr\backslashnMETHODS\backslashr\backslashnTwo devices for PPG-based ABI assessments (Vicorder, Vascular Explorer) were tested and compared against Doppler in 56 putatively healthy subjects. We determined acceptance, time requirements, agreement of repeat measurements, agreement with Doppler and intra- and inter-observer concordances for both devices and compared the results. Differences between cuff inflation- and deflation-based methods were also studied for Vascular Explorer.\backslashr\backslashnRESULTS\backslashr\backslashnAcceptance was similar for both devices but Vascular Explorer was more time consuming. Agreement of multiple measurements was moderate for both methods highlighting the importance of measurement replicates. Both automated devices showed significantly higher ABI compared to Doppler which can be traced back to higher brachial pressures (Vicorder) or higher ankle pressures (Vascular Explorer). This effect is more pronounced for Vascular Explorer but can be ameliorated using the deflation method of measurement. Intra-observer concordances were similar. Inter-observer concordance was non-significantly better for Vicorder.\backslashr\backslashnCONCLUSIONS\backslashr\backslashnBoth devices proved to be feasible in epidemiologic studies, but compared to Doppler, do not constitute an advantage regarding time requirement and accuracy of ABI assessment. Since PPG-based ABI values are inflated compared to Doppler, it will be necessary to adjust Doppler-based cut-offs for risk stratification. BACKGROUND Ankle-brachial-Index (ABI) measured by manual Dopplersonography is an easily assessable marker of global cardiovascular risk. The aim of this study was to establish novel photo-plethysmography (PPG)-based ABI assessments in an epidemiologic context and to compare its results with those of Doppler. METHODS Two devices for PPG-based ABI assessments (Vicorder, Vascular Explorer) were tested and compared against Doppler in 56 putatively healthy subjects. We determined acceptance, time requirements, agreement of repeat measurements, agreement with Doppler and intra- and inter-observer concordances for both devices and compared the results. Differences between cuff inflation- and deflation-based methods were also studied for Vascular Explorer. RESULTS Acceptance was similar for both devices but Vascular Explorer was more time consuming. Agreement of multiple measurements was moderate for both methods highlighting the importance of measurement replicates. Both automated devices showed significantly higher ABI compared to Doppler which can be traced back to higher brachial pressures (Vicorder) or higher ankle pressures (Vascular Explorer). This effect is more pronounced for Vascular Explorer but can be ameliorated using the deflation method of measurement. Intra-observer concordances were similar. Inter-observer concordance was non-significantly better for Vicorder. CONCLUSIONS Both devices proved to be feasible in epidemiologic studies, but compared to Doppler, do not constitute an advantage regarding time requirement and accuracy of ABI assessment. Since PPG-based ABI values are inflated compared to Doppler, it will be necessary to adjust Doppler-based cut-offs for risk stratification.

DOI: 10.1186/1471-2261-13-81

Projects: Genetical Statistics and Systems Biology

Publication type: Journal article

Journal: BMC cardiovascular disorders

Human Diseases: No Human Disease specified

Citation: BMC Cardiovasc Disord 13(1),81

Date Published: 1st Dec 2013

Registered Mode: imported from a bibtex file

Authors: Andrej Teren, Frank Beutner, Kerstin Wirkner, Markus Loeffler, Markus Scholz

Help
help Submitter
Citation
Teren, A., Beutner, F., Wirkner, K., Loeffler, M., & Scholz, M. (2013). Validity, intra- and inter-observer reliability of automated devices for the assessment of ankle brachial index using photo-plethysmography. In BMC Cardiovascular Disorders (Vol. 13, Issue 1). Springer Science and Business Media LLC. https://doi.org/10.1186/1471-2261-13-81
Activity

Views: 1155

Created: 14th Sep 2020 at 13:35

Last updated: 7th Dec 2021 at 17:58

help Tags

This item has not yet been tagged.

help Attributions

None

Related items

Powered by
(v.1.13.0-master)
Copyright © 2008 - 2021 The University of Manchester and HITS gGmbH
Institute for Medical Informatics, Statistics and Epidemiology, University of Leipzig

By continuing to use this site you agree to the use of cookies