Sevoflurane and Isoflurane-Pharmacokinetics, Hemodynamic Stability, and Cardioprotective Effects During Cardiopulmonary Bypass

Abstract:

OBJECTIVES This study aimed to evaluate the pharmacokinetic profiles of sevoflurane and isoflurane during use of minimized extracorporeal circulation to perform coronary artery bypass graft surgery. Furthermore, cardiovascular stability during bypass and the postoperative release of troponins were evaluated. DESIGN Prospective, randomized study. SETTING University hospital. PARTICIPANTS The study comprised 31 adult patients undergoing coronary artery bypass grafting. INTERVENTIONS The pharmacokinetic measurements of the concentration of the volatile anesthetics in the arterial and venous blood, air inlet, air outlet, and gas exhaust of the extracorporeal circulation were recorded. Secondary end-points were cardiovascular stability during bypass, amount of postoperative release of troponin, time to extubation, time to discharge from the intensive care unit and the hospital, and 30-day mortality. MEASUREMENTS AND MAIN RESULTS Thirty patients completed the protocol. The pharmacokinetics of isoflurane and sevoflurane were almost identical, with a rapid wash-in (time to reach 50% of arterial steady state) concentration of 0.87\pm0.97 minutes and 1.14\pm0.35 minutes for isoflurane and sevoflurane, respectively, and a biphasic venous elimination with a terminal half-life of approximately 10 minutes for both compounds. There was a correlation between the gas inlet and the gas exhaust of the extracorporeal circulation. No difference in cardiovascular stability was found. High-sensitivity troponin concentrations on the first postoperative morning were 0.355\pm0.312 µg/mL and 0.225\pm0.111 µg/mL in the isoflurane and sevoflurane groups, respectively (p = 0.147). CONCLUSIONS The study found similar pharmacokinetics regarding wash-in and wash-out for sevoflurane and isoflurane. In addition, no difference in cardiovascular stability was found. The markers of cardiac damage were not different between the two anesthetics. Based on these data, sevoflurane and isoflurane might be used equivalently in patients undergoing coronary artery bypass graft surgery with extracorporeal circulation.

DOI: 10.1053/j.jvca.2016.07.011

Projects: Genetical Statistics and Systems Biology

Publication type: Journal article

Journal: Journal of cardiothoracic and vascular anesthesia

Human Diseases: No Human Disease specified

Citation: Journal of Cardiothoracic and Vascular Anesthesia 30(6):1494-1501

Date Published: 1st Dec 2016

Registered Mode: imported from a bibtex file

Authors: David Freiermuth, Berend Mets, Daniel Bolliger, Oliver Reuthebuch, Thomas Doebele, Markus Scholz, Michael Gregor, Matthias Haschke, Manfred Daniel Seeberger, Jens Fassl

Help
help Submitter
Citation
Freiermuth, D., Mets, B., Bolliger, D., Reuthebuch, O., Doebele, T., Scholz, M., Gregor, M., Haschke, M., Seeberger, M. D., & Fassl, J. (2016). Sevoflurane and Isoflurane—Pharmacokinetics, Hemodynamic Stability, and Cardioprotective Effects During Cardiopulmonary Bypass. In Journal of Cardiothoracic and Vascular Anesthesia (Vol. 30, Issue 6, pp. 1494–1501). Elsevier BV. https://doi.org/10.1053/j.jvca.2016.07.011
Activity

Views: 1014

Created: 14th Sep 2020 at 13:44

Last updated: 7th Dec 2021 at 17:58

help Tags

This item has not yet been tagged.

help Attributions

None

Related items

Powered by
(v.1.13.0-master)
Copyright © 2008 - 2021 The University of Manchester and HITS gGmbH
Institute for Medical Informatics, Statistics and Epidemiology, University of Leipzig

By continuing to use this site you agree to the use of cookies